ble: ap807: clean-up PLL configuration sequence
Remove pll powerdown from pll configuration sequence to improve
stability. Remove redundant cases, which no longer exist.
Also get rid of irrelevant definition of CPU_2200_DDR_1200_RCLK_1200,
which is not used by 806/807.

Change-Id: If911e7dee003dfb9a42fafd7ffe34662f026fd23
Signed-off-by: Alex Leibovich <alexl@marvell.com>
1 parent 57adbf3 commit 85d2ed150158e4c92f3238342a76dea4c30d7a95
@Alex Leibovich Alex Leibovich authored on 10 Feb 2019
Marcin Wojtas committed on 6 Jun 2020
Showing 3 changed files
View
drivers/marvell/ap807_clocks_init.c
View
include/drivers/marvell/aro.h
View
plat/marvell/armada/a8k/common/plat_ble_setup.c