allwinner: Synchronize PMIC enumerations
Ensure that the default (zero) value represents the case where we take
no action. Previously, if a PLAT=sun50i_a64 build was booted on an
unknown SoC ID, it would be treated as an H5 at shutdown.

This removes some duplicate code and fixes error propagation on H6.

Signed-off-by: Samuel Holland <samuel@sholland.org>